Issued on:2008-12-01

 Annex(2)

To The Accreditation Certificate No. JAS Test - 006 Dated 2007-08-05

For Middle East Laboratory and Technical Services/ Amman


Scope of Accreditation

Testing of Electrical Products
 

 

Tested Parameter/
Type of Test
 

Test Methods/Standards

Plugs and sokets (thermoplastic and without cover)

Protection aginst electrical shock

§   International Standard IEC 60884-1:2002 – Clause 10.1 & 10.3.

Resistance to heat (only on insulating material necessary to retain current- carrying Parts and parts of the earthing circuit in position)

§   International Standard IEC 60884-1:2002 – Clause 25.1. & 25.2.

Insulating resistance and electrical strength.

§   International Standard IEC 60884-1:2002 – Clause 17.1 & 17.2.

Audio,Video and similar electronic apparatous

Fault condition test with opening/vents closed

§   International Standard IEC 60065:2001 – Clause 11.2.

Heating under normal operating conditions

§   International Standard IEC 60065:2001 – Clause 7.1

Power supply cord conductors–cross sectional

§   International Standard IEC 60065:2001 – Clause 16.2.

Constructional requirments with regard to the protection against electric shcok

§   International Standard IEC 60065:2001 – Clause 8 (excliding 8.7, 8.12, 8.16, 8.17, 8.18 & 8.21).

Electrical shcokhazard under normal operating conditions

§   International Standard IEC 60065:2001 – Clause 9.1.1.2, 9.1.3, 9.1.4, 9.1.5 & 9.1.7 .

Clearances

§   International Standard IEC 60065:2001 – Clause 13.3.2.

Creepage distances

§   International Standard IEC 60065:2001 – Clause 13.4.

IT Products

Maximum temperatures

§   International Standard IEC 60950:2001 – Clause 4.5.1.

Touch current

§   International Standard IEC 60950:2001 – Clause 5.1.1 to 5.1.6.

Electrical Strength

§   International Standard IEC 60950:2001 – Clause 5.2.

Protection aqainst electrical shcok

§   International Standard IEC 60950:2001 – Clause 2.1.1.1  to  2.1.1.4 & 2.1.1.6.

Provision for earthing

§   International Standard IEC 60950:2001 – Clause 2.6.3.

Clearances

§   International Standard IEC 60950:2001 – Clause 2.10.3.2.

Creepage distances

§   International Standard IEC 60950:2001 – Clause 2.10.4.

Luminaires (Tungsten filament and fluorescent lamps)

Leakage Current

§   International Standard IEC 60598-1:2006; - Clause 10.3.

Insulation resistance and electric stregth

§   International Standard IEC 60598-1:2006; -  Clause 10.2.

Provision for earthing

§   International Standard IEC 60598-1:2006; -  Clause 7.2.3.

 

List of Employees in the laboratory that are technically responsible for issuing the test reports in the scope of accreditation:

   1- Deputy Manager / Eng. Mazen Al-Momani.

   2- Lab Engineer / Eng. Salameh Sakarneh.

   3- Lab Engineer / Eng. Abdulla Qatawneh.