Issued on:2008-12-01
Annex(2)
Scope of Accreditation
Testing of
Electrical Products
|
Tested
Parameter/ |
Test Methods/Standards |
Plugs and sokets (thermoplastic and without cover) |
|
|
Protection aginst electrical shock |
§ International Standard IEC 60884-1:2002 Clause 10.1 & 10.3. |
|
Resistance to heat (only on insulating material necessary to retain current- carrying Parts and parts of the earthing circuit in position) |
§ International Standard IEC 60884-1:2002 Clause 25.1. & 25.2. |
|
Insulating resistance and electrical strength. |
§ International Standard IEC 60884-1:2002 Clause 17.1 & 17.2. |
Audio,Video and similar electronic apparatous |
|
|
Fault condition test with opening/vents closed |
§ International Standard IEC 60065:2001 Clause 11.2. |
|
Heating under normal operating conditions |
§ International Standard IEC 60065:2001 Clause 7.1 |
|
Power supply cord conductorscross sectional |
§ International Standard IEC 60065:2001 Clause 16.2. |
|
Constructional requirments with regard to the protection against electric shcok |
§ International Standard IEC 60065:2001 Clause 8 (excliding 8.7, 8.12, 8.16, 8.17, 8.18 & 8.21). |
|
Electrical shcokhazard under normal operating conditions |
§ International Standard IEC 60065:2001 Clause 9.1.1.2, 9.1.3, 9.1.4, 9.1.5 & 9.1.7 . |
|
Clearances |
§ International Standard IEC 60065:2001 Clause 13.3.2. |
|
Creepage distances |
§ International Standard IEC 60065:2001 Clause 13.4. |
IT Products |
|
| Maximum temperatures |
§ International Standard IEC 60950:2001 Clause 4.5.1. |
|
Touch current |
§ International Standard IEC 60950:2001 Clause 5.1.1 to 5.1.6. |
|
Electrical Strength |
§ International Standard IEC 60950:2001 Clause 5.2. |
|
Protection aqainst electrical shcok |
§ International Standard IEC 60950:2001 Clause 2.1.1.1 to 2.1.1.4 & 2.1.1.6. |
|
Provision for earthing |
§ International Standard IEC 60950:2001 Clause 2.6.3. |
|
Clearances |
§ International Standard IEC 60950:2001 Clause 2.10.3.2. |
|
Creepage distances |
§ International Standard IEC 60950:2001 Clause 2.10.4. |
Luminaires (Tungsten filament and fluorescent lamps) |
|
|
Leakage Current |
§ International Standard IEC 60598-1:2006; - Clause 10.3. |
|
Insulation resistance and electric stregth |
§ International Standard IEC 60598-1:2006; - Clause 10.2. |
|
Provision for earthing |
§ International Standard IEC 60598-1:2006; - Clause 7.2.3. |
List of Employees in the laboratory that are technically responsible for issuing the test reports in the scope of accreditation:
1- Deputy Manager / Eng. Mazen Al-Momani.
2- Lab Engineer / Eng. Salameh Sakarneh.
3- Lab Engineer / Eng. Abdulla Qatawneh.